BASIC INFO
Certification/Class (Standard): KN95 (GB2626-2006)
Filter performance – (must be ≥ X% efficient): ≥ 95%
Test agent: NaCl
Flow rate: 85 L/min
Total inward leakage (TIL)* –tested on human subjects each performing exercises: ≤ 8% leakage (arithmetic mean)
Inhalation resistance – max pressure drop: ≤ 350 Pa
Exhalation resistance -max pressure drop: ≤ 250 Pa
Flow rate: 85 L/min
Exhalation valve leakage requirement: Depressurization n to 0 Pa ≥ 20 sec
Force applied: -1180 Pa